An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity all together.
Deye hybrid inverters include single phase 3-16kW and three-phase 8-12kW, For the SUN-3K-SG04LP1-24-EU, it uses 24V battery bank and the rest of them adopts 48V battery. Also, the SUN-16K-SG01LP1-EU is the max single phase hybrid inverter on the global market.
The Grid-interactive inverter consists of several hardware elements. The Grid-interactive inverter controls and monitors the connection of the electricity from the power plants. In addition, it also controls the disconnection of excess power from the plants. It ensures the dispatch of power at the peak time based on demand.
Blade Warranty: 1 year for all wind turbine blades.
Generator Warranty: 10 years of guaranteed performance for the permanent magnet generator.
Free Replacement for Small Parts: Enjoy hassle-free replacement of minor components.
Installation Support: Detailed manuals and online technical assistance to guide your setup.
OEM & ODM Services: Customized branding and product design to meet your specific requirements.
100% Secure Transactions: SSL-encrypted payment gateway for maximum safety.
Multiple Payment Methods: We accept Credit Cards, PayPal, T/T, and Alibaba Trade Assurance for global buyers.
Buyer Protection Guarantee: On-time delivery, product quality assurance, and full refund options for complete peace of mind.
Flexible Shipping Options: We cooperate with trusted freight forwarders and offer sea freight and air freight solutions.
Fast Global Dispatch: Most orders ship within 2–10 days, while in-stock items are dispatched within 24 hours.
Secure Packaging: Durable, anti-damage packaging ensures safe delivery of every wind turbine component.
Real-Time Tracking: Every order comes with a tracking number for full visibility during transportation.
Model
|
SUN-5K-SGO4LP3-EU
|
SUN-6K-SGO4LP3-EU
|
SUN-8K-SG04LP3-EU
|
SUN-10K-SG04LP3-EU
|
SUN-12K-SG04LP3-EU
|
Battery Input Data
|
|||||
Battery Type
|
Lead-acid or Li-lon
|
||||
Battery Voltage Range (V)
|
40~60
|
||||
Max.Charging Current (A)
|
120
|
150
|
190
|
210
|
240
|
Max.Discharging Current (A)
|
120
|
150
|
190
|
210
|
240
|
External Temperature Sensor
|
Yes
|
||||
Charging Curve
|
3 Stages /Equalization
|
||||
Charging Strategy for Li-lon Battery
|
Self-adaption to BMS
|
||||
PV String Input Data
|
|||||
Max.DC Input Power(W)
|
6500
|
7800
|
10400
|
13000
|
15600
|
Rated PV Input Voltage (V)
|
550(160~800)
|
||||
Start-up Voltage (V)
|
160
|
||||
MPPT Voltage Range (V)
|
200-650
|
||||
Full Load DC Voltage Range (V)
|
350-650
|
||||
PV Input Current (A)
|
13+13
|
26+13
|
|||
Max.PVISC(A)
|
17+17
|
34+17
|
|||
Number ofMPPT /Strings per MPPT
|
2/1+1
|
2/2+1
|
|||
AC Output Data
|
|||||
Rated AC Output and UPS Power (W)
|
5000
|
6000
|
8000
|
10000
|
12000
|
Max.AC Output Power(W)
|
5500
|
6600
|
8800
|
11000
|
13200
|
AC Output Rated Current (A)
|
7.6
|
9.1
|
12.1
|
15.2
|
18.2
|
Max.AC Current(A)
|
11.4
|
13.6
|
18.2
|
22.7
|
27.3
|
Max.Continuous AC Passthrough(A)
|
45
|
||||
PeakPower(off grid)
|
2 time of rated power,10 S
|
||||
Power Factor
|
0.8 leading to 0.8 lagging
|
||||
Output Frequency and Voltage
|
50/60Hz;3L/N/PE 220/380,230/400Vac
|
||||
Grid Type
|
Three Phase
|
||||
DC injection current (mA)
|
THD<3%(Linear load<1.5%)
|
||||
Efficiency
|
|||||
Max.Efficiency
|
97.60%
|
||||
Euro Efficiency
|
97.00%
|
||||
MPPT Efficiency
|
99.90%
|
||||
Protection
|
|||||
Integrated
|
PV Input Lightning Protection,Anti-islanding Protection,PV String Input Reverse Polarity Protection,
Insulation Resistor Detection,Residual Current Monitoring Unit,Output Over Current Protection,
|
||||
Output Over Voltage Protection
|
DC Type lI/AC Type IIl
|
||||
Certifications and Standards
|
|||||
Grid Regulation
|
CEI0-21,VDE-AR-N 4105,NRS 097,IEC 62116,IEC 61727,G99,G98,
|
||||
VDE 0126-1-1,RD 1699,C10-11
|
|||||
Safety EMC /Standard
|
IEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN 62109-2
|
||||
General Data
|
|||||
Operating Temperature Range (C)
|
-45~60℃,>45℃ derating
|
||||
Cooling
|
Smart cooling
|
||||
Noise (dB)
|
<45 dB
|
||||
Communication with BMS
|
RS485;CAN
|
||||
Weight (kg)
|
33.6
|
||||
Size (mm)
|
422Wx699.3Hx279D
|
||||
Protection Degree
|
IP65
|
||||
Installation Style
|
Wall-mounted
|
||||
Warranty
|
5 years
|
Yes, a residential wind generator can power lights, small appliances, and even supplement solar systems, depending on wind conditions and turbine size.
Our upgraded fiberglass blades start generating electricity at wind speeds of 3m/s, allowing it to generate electricity efficiently even in moderate wind areas.
Absolutely. Our turbines are designed for farms, cabins, vacation homes, and other areas where electricity is limited or unavailable.
Regularly check blades, bolts, and wiring. Our turbines are low-maintenance, and most parts are durable with long service lif
Vertical axis wind turbines (VAWT) are great for low-wind areas and urban settings, while horizontal axis turbines (HAWT) are more efficient in open areas with higher wind speeds.
Permit requirements vary by country and region. We recommend checking local regulations before installation. Our team can provide guidance.
If you want to store energy for use when wind is low, a battery system is recommended. Otherwise, turbines can feed electricity directly into your home or hybrid system.
We’d like to work with you